Ambient Equilibration Cabin temperature: 25C Sensor type: RS41 Ambient pressure: 694mb Ambient temperature: 9C Ambient RH: 89% Temperature equilibration accuracy: 0.1C RH equilibration accuracy: 5.0% Temperature equilibration at time: 3.6s, RS41 T sensor time constants: 5.0 RH equilibration at time: -3.0s, RS41 RH sensor time constants: -0.1 Pressure: same equilibration time used as for temperature Wind equilibration: 10.0s Description D20220901_122720.7 220840711 AL-91, 20220901H1 WP-3D Orion, N42RF Data type: AVAPS SOUNDING DATA, Channel 7 Sonde model: RSS421 Thermo sensor: RSS421 This file appears to have a late launch detect signal. The pressure diagnosed launch time will be used instead of the launch time at the launch (LAU) line. Diagnosed launch time: 2022-09-01 10:06:44.0 LAU launch line time: 2022-09-01 12:27:20.0 Fast Fall Test Not enough points for the fast fall check File Processing Data type: AVAPS SOUNDING DATA, Channel 7 Sonde model: RSS421 Thermo sensor: RSS421 This file appears to have a late launch detect signal. The pressure diagnosed launch time will be used instead of the launch time at the launch (LAU) line. Diagnosed launch time: 2022-09-01 10:06:44.0 LAU launch line time: 2022-09-01 12:27:20.0 Processing Steps QC processing completed (in 2.0s) Levels created (in less than 1.0s) WMO message coded (in less than 1.0s) QC Data Recovery Statistics 34891 raw data records 7 ( 0.0%) raw data records had PTU checksum errors 10 ( 0.0%) raw data records had GPS checksum errors 1 ( 0.0%) raw data records had both PTU and GPS checksum errors pres : input file reported 17192 ( 49.3%) values, QC retained 559 ( 3.3%), overall rate: 1.6% tdry : input file reported 17188 ( 49.3%) values, QC retained 559 ( 3.3%), overall rate: 1.6% RH : input file reported 17154 ( 49.2%) values, QC retained 558 ( 3.3%), overall rate: 1.6% winds: input file reported 34235 ( 98.1%) values, QC retained 1098 ( 3.2%), overall rate: 3.1% QC Height Integration Upward integration starts @ 0.0m and stops @ 3155.1m Downward integration starts @ 3213.8m and stops @ 3213.8m QC Processing Errors - Filter check failed for pressure - Filter check failed for VVpressure - Filter check failed for Tdry - Filter check failed for RH - Final smoothing failed for VV pressure - Final smoothing failed for pressure - Final smoothing failed for blended pressure - Unable to compute vertical velocity from pressure (temperature sensor time constant) - Unable to compute vertical velocity from pressure (temperature sensor time constant) - Unable to dynamically adjust temperature - Final smoothing failed for tdry - Final smoothing failed for RH - Final smoothing failed for U winds - Unable to compute vertical velocity from pressure (final) - Unable to compute vertical velocity from pressure (final) - Unable to dynamically adjust winds QC for GPS Altitude Points which failed the limit check: 0 Points which failed the number of satellites check: 6 Points which failed the buddy check: 15 Points which failed the Q/C filter check: 0 QC for GPS Position Points which failed the latitude limit check: 0 Points which failed the longitude limit check: 0 Points which failed the number of satellites check: 13 Points which failed the latitude buddy check: 0 Points which failed the longitude buddy check: 0 Points which failed the latitude Q/C filter check: 31 Points which failed the longitude Q/C filter check: 2 QC for Pressure Points which failed the limit check: 0 Points which failed the buddy check: 0 Points which failed the outlier check: 0 Points which failed the Q/C filter check: 0 Unable to compute vertical velocity from pressure (temperature sensor time constant, usually due to spline fit failure) Unable to compute vertical velocity from pressure (final, usually due to spline fit failure) QC for Relative Humidity Points which failed the limit check: 0 Points which failed the buddy check: 1 Points which failed the outlier check: 0 Points which failed the Q/C filter check: 0 Points which failed the lower limit check: 0 Points which failed the upper limit check: 0 Points which failed the lower limit check: 0 Points which failed the upper limit check: 0 QC for Temperature Points which failed the limit check: 0 Points which failed the buddy check: 0 Points which failed the outlier check: 0 Points which failed the Q/C filter check: 0 Unable to dynamically adjust temperature (usually due to spline fit failure) QC for VV Pressure Points which failed the limit check: 0 Points which failed the buddy check: 0 Points which failed the outlier check: 0 Points which failed the Q/C filter check: 0 Unable to compute vertical velocity from vv pressure (temperature sensor time constant, usually due to spline fit failure) Unable to compute vertical velocity from vv pressure (final, usually due to spline fit failure) QC for Winds Points which failed the wind speed limit check: 0 Points which failed the wind direction limit check: 0 Points which failed the number of satellites check: 1 Points which failed the wind error check: 14 Points which failed the buddy check: 0 Outlier check disabled Q/C filter check disabled Points which failed the vertical velocity check: 0 Unable to dynamically adjust winds (usually due to spline fit failure) Surface Observation Splash time (time of the last usable frame): 8722.25s Extrapolated surface time: 8722.79s Surface Wind Determination Adjusted altitude of last wind is 0.0m, surface wind was not coded PTU/wind offset is 0.00s (PTU observations lead wind observations by 0.00s)