16:58:11 20190916: Acquisition stopped. 16:58:18 20190916: Changes to the configuration will not take effect until the program is reset. Press the Reset Program button to initiate new settings. 16:58:49 20190916: PADS program RESET. 16:58:49 20190916: IP Instrument Driver 0, stopped. 16:58:49 20190916: IP Instrument Driver 1, stopped. 16:58:49 20190916: CDP Instrument Driver 2, stopped. 16:58:49 20190916: Hotwire LWC Instrument Driver 3, stopped. 16:58:49 20190916: CAS Instrument Driver 4, stopped. 16:58:49 20190916: PbP CAS Instrument Driver 5, stopped. 16:58:49 20190916: Combo Instrument Driver 6, stopped. 16:58:51 20190916: PADS program started. 16:58:51 20190916: IP Instrument Driver 0 started. 16:58:52 20190916: IP Instrument Driver 1 started. 16:58:52 20190916: CDP Instrument Driver 2 started. 16:58:52 20190916: Hotwire LWC Instrument Driver 3 started. 16:58:52 20190916: CAS Instrument Driver 4 started. 16:58:52 20190916: PbP CAS Instrument Driver 5 started. 16:58:52 20190916: Combo Instrument Driver 6 started. 16:58:52 20190916: Enabling Instrument #0, PIP. 16:58:52 20190916: Enabling Instrument #2, CDP. 16:58:52 20190916: Enabling Instrument #1, CIP. 16:58:52 20190916: Enabling Instrument #6, Combo. 16:58:52 20190916: Summary Display, Display # 7, started. 16:58:52 20190916: Combo Display, Display # 6, Instrument # 6, started. 16:58:52 20190916: PbP CAS Display, Display # 5, Instrument # 5, started. 16:58:53 20190916: CAS Display, Display # 4, Instrument # 4, started. 16:58:53 20190916: Hotwire LWC Display, Display # 3, Instrument # 3, started. 16:58:53 20190916: CDP Display, Display # 2, Instrument # 2, started. 16:58:53 20190916: IP Display, Display # 1, Instrument # 1, started. 16:58:53 20190916: IP Display, Display # 0, Instrument # 0, started. 16:58:53 20190916: Saving Configuration file: C:\DMT\PADS Data\20190916\PADS.ini 16:58:55 20190916: Acquisition started. 16:58:56 20190916: Instrument Driver 0,PIP, is being initialized. 16:58:56 20190916: Instrument Driver 1,CIP, is being initialized. 16:58:56 20190916: Instrument Driver 2, CDP, is being initialized. 16:58:56 20190916: Instrument Driver 6,Combo, is being initialized. *** 16:58:57 20190916: Warning 1073676294 occurred at VISA Read in IP Get Data.vi->IP 26.vi Possible reason(s): VISA: (Hex 0x3FFF0006) The number of bytes transferred is equal to the requested input count. More data might be available. *** 16:58:58 20190916: Warning 1073676294 occurred at VISA Read in IP Get Data.vi->IP 27.vi Possible reason(s): VISA: (Hex 0x3FFF0006) The number of bytes transferred is equal to the requested input count. More data might be available. *** 17:40:52 20190916: Error 23 occurred at Sealevel.lvlib:Read.vi:3 > Sealevel.lvlib:read_all.vi:2 > IP 27.viOther image card error: 23 Possible reason(s): LabVIEW: Bad external code format. 17:44:27 20190916: Recording started. 00:17:30 20190917: Acquisition stopped. 00:17:31 20190917: IP Instrument Driver 0, stopped. 00:17:31 20190917: IP Instrument Driver 1, stopped. 00:17:31 20190917: CDP Instrument Driver 2, stopped. 00:17:31 20190917: Hotwire LWC Instrument Driver 3, stopped. 00:17:31 20190917: CAS Instrument Driver 4, stopped. 00:17:31 20190917: PbP CAS Instrument Driver 5, stopped. 00:17:31 20190917: Combo Instrument Driver 6, stopped. 00:17:33 20190917: PADS program stopped.