Monitor statistics generated at: 20152951800 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 1.56 1.88 8 4.75 5.25 0 8 power supply -5.2VDC -5.20 0.00 8 -5.50 -4.75 8 0 power supply +28VDC 27.98 0.16 8 26.60 29.40 8 0 power supply +15VDC 15.41 0.03 8 14.50 15.75 8 0 power supply -15VDC -15.28 0.00 8 -15.50 -14.50 8 0 spacek supply +5VDC 4.99 0.00 8 4.75 5.25 8 0 spacek supply +12VDC 12.12 0.02 8 11.75 12.25 8 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 8 0.90 1.10 8 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 8 0.90 1.10 8 0 SW fault (TTL) 1.00 0.00 8 0.90 1.10 8 0 Pulse fault (TTL) 1.00 0.00 8 0.90 1.10 8 0 temperature (indoor) 55.90 5.65 26 5.00 35.00 0 26 temperature (warm load) 56.19 1.43 26 -50.00 50.00 0 26 temperature (RF plate) 60.77 1.40 26 -50.00 50.00 0 26 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 62.54 40.50 3168 57.00 63.00 3075 93 Transmitted RF Power History Past 10/100/1000 Hours: 62.42/ 62.24/ 62.27 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0