Monitor statistics generated at: 20152942000 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 4.97 0.23 10 4.75 5.25 7 3 power supply -5.2VDC -5.20 0.00 10 -5.50 -4.75 10 0 power supply +28VDC 29.43 0.35 10 26.60 29.40 6 4 power supply +15VDC 15.37 0.02 10 14.50 15.75 10 0 power supply -15VDC -15.28 0.00 10 -15.50 -14.50 10 0 spacek supply +5VDC 4.99 0.00 10 4.75 5.25 10 0 spacek supply +12VDC 12.12 0.02 10 11.75 12.25 10 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 10 0.90 1.10 10 0 SW fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 Pulse fault (TTL) 1.00 0.00 10 0.90 1.10 10 0 temperature (indoor) 60.94 1.58 30 5.00 35.00 0 30 temperature (warm load) 54.00 1.27 30 -50.00 50.00 0 30 temperature (RF plate) 61.02 0.95 30 -50.00 50.00 0 30 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower 62.57 41.66 3600 57.00 63.00 3567 33 Transmitted RF Power History Past 10/100/1000 Hours: 62.39/ 62.23/ 62.26 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0