Monitor statistics generated at: 20152581824 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.11 0.00 5 4.75 5.25 5 0 power supply -5.2VDC -5.21 0.00 5 -5.50 -4.75 5 0 power supply +28VDC 28.23 0.02 5 26.60 29.40 5 0 power supply +15VDC 15.38 0.00 5 14.50 15.75 5 0 power supply -15VDC -15.31 0.03 5 -15.50 -14.50 5 0 spacek supply +5VDC 3.00 2.73 5 4.75 5.25 3 2 spacek supply +12VDC 7.30 6.58 5 11.75 12.25 3 2 2.1 GHzPhaseLock (TTL) 0.60 0.55 5 0.90 1.10 3 2 15.4 GHzPhaseLock (TTL) 0.60 0.55 5 0.90 1.10 3 2 SW fault (TTL) 1.00 0.00 5 0.90 1.10 5 0 Pulse fault (TTL) 1.00 0.00 5 0.90 1.10 5 0 temperature (indoor) 18.18 48.49 13 5.00 35.00 0 13 temperature (warm load) 14.54 46.47 13 -50.00 50.00 6 7 temperature (RF plate) 16.53 40.95 13 -50.00 50.00 6 7 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower NaN -Inf 784 57.00 63.00 0 784 Transmitted RF Power History Past 10/100/1000 Hours: 62.40/ 62.23/ 62.26 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0