Monitor statistics generated at: 20152581800 (YYYYJJJHHMM) Parameter Name Mean StdDev Count LoLimit HiLimit In Out power supply +5VDC 5.12 0.00 2 4.75 5.25 2 0 power supply -5.2VDC -5.21 0.00 2 -5.50 -4.75 2 0 power supply +28VDC 31.59 3.45 2 26.60 29.40 1 1 power supply +15VDC 15.38 0.00 2 14.50 15.75 2 0 power supply -15VDC -15.31 0.03 2 -15.50 -14.50 2 0 spacek supply +5VDC 5.00 0.00 2 4.75 5.25 2 0 spacek supply +12VDC 12.11 0.00 2 11.75 12.25 2 0 2.1 GHzPhaseLock (TTL) 1.00 0.00 2 0.90 1.10 2 0 15.4 GHzPhaseLock (TTL) 1.00 0.00 2 0.90 1.10 2 0 SW fault (TTL) 1.00 0.00 2 0.90 1.10 2 0 Pulse fault (TTL) 1.00 0.00 2 0.90 1.10 2 0 temperature (indoor) 61.18 0.41 6 5.00 35.00 0 6 temperature (warm load) 54.77 0.72 6 -50.00 50.00 0 6 temperature (RF plate) 48.42 2.26 6 -50.00 50.00 4 2 UPSInputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputVoltage NaN 0.00 0 114.00 126.00 0 0 UPSOutputCurrent NaN 0.00 0 0.00 5.70 0 0 UPSBatteryVoltage NaN 0.00 0 13.25 14.50 0 0 TransmittedRFPower NaN -Inf 784 57.00 63.00 0 784 Transmitted RF Power History Past 10/100/1000 Hours: 62.40/ 62.23/ 62.26 TWTA attempted restarts (5 min thru 55 min) =0/0/0/0/0/0