14:43:08 20140915: PADS program started. 14:43:08 20140915: PIP Instrument Driver 0 started. 14:43:08 20140915: Enabling Instrument #0, PIP. 14:43:09 20140915: CIP Instrument Driver 1 started. 14:43:09 20140915: Enabling Instrument #1, CIP. 14:43:09 20140915: CDP Instrument Driver 2 started. 14:43:09 20140915: Enabling Instrument #2, CDP. 14:43:09 20140915: Hotwire_LWC Instrument Driver 3 started. 14:43:11 20140915: CAS Instrument Driver 4 started. 14:43:11 20140915: Enabling Instrument #4, CAS. 14:43:12 20140915: PBP Instrument Driver 5 started. 14:43:12 20140915: Enabling Instrument #5, PBP. 14:43:12 20140915: CCP Summary Instrument Driver 6 started. 14:43:12 20140915: Enabling Instrument #6, CCP Summary. 14:43:12 20140915: CCP Summary Display, Display # 6, Instrument # 6, started. 14:43:13 20140915: PBP Display, Display # 5, Instrument # 5, started. 14:43:13 20140915: CAS Display, Display # 4, Instrument # 4, started. 14:43:13 20140915: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 14:43:13 20140915: CDP Display, Display # 2, Instrument # 2, started. 14:43:13 20140915: CIP Display, Display # 1, Instrument # 1, started. 14:43:14 20140915: PIP Display, Display # 0, Instrument # 0, started. 14:43:14 20140915: Saving Configuration file: C:\PADS Data\20140915\PADS.ini 14:43:23 20140915: Acquisition started. 20:56:24 20140915: Acquisition stopped. 20:56:24 20140915: Instrument Driver 0,PIP, is being initialized. *** 20:56:24 20140915: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. *** 20:56:24 20140915: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 20:56:24 20140915: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 20:56:24 20140915: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 20:56:24 20140915: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. 20:56:36 20140915: PIP Instrument Driver 0, stopped. 20:56:36 20140915: CIP Instrument Driver 1, stopped. 20:56:36 20140915: CDP Instrument Driver 2, stopped. 20:56:36 20140915: Hotwire_LWC Instrument Driver 3, stopped. 20:56:36 20140915: CAS Instrument Driver 4, stopped. 20:56:36 20140915: PBP Instrument Driver 5, stopped. 20:56:36 20140915: CCP Summary Instrument Driver 6, stopped. 20:56:38 20140915: PADS program stopped.