04:08:10 20140825: PADS program started. 04:08:10 20140825: PIP Instrument Driver 0 started. 04:08:10 20140825: Enabling Instrument #0, PIP. 04:08:10 20140825: CIP Instrument Driver 1 started. 04:08:10 20140825: Enabling Instrument #1, CIP. 04:08:10 20140825: CDP Instrument Driver 2 started. 04:08:11 20140825: Enabling Instrument #2, CDP. 04:08:11 20140825: Hotwire_LWC Instrument Driver 3 started. 04:08:13 20140825: CAS Instrument Driver 4 started. 04:08:13 20140825: Enabling Instrument #4, CAS. 04:08:13 20140825: PBP Instrument Driver 5 started. 04:08:13 20140825: Enabling Instrument #5, PBP. 04:08:14 20140825: CCP Summary Instrument Driver 6 started. 04:08:17 20140825: CCP Summary Display, Display # 6, Instrument # 6, started. 04:08:17 20140825: PBP Display, Display # 5, Instrument # 5, started. 04:08:17 20140825: CAS Display, Display # 4, Instrument # 4, started. 04:08:17 20140825: Enabling Instrument #6, CCP Summary. 04:08:17 20140825: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 04:08:17 20140825: CDP Display, Display # 2, Instrument # 2, started. 04:08:18 20140825: CIP Display, Display # 1, Instrument # 1, started. 04:08:18 20140825: PIP Display, Display # 0, Instrument # 0, started. 04:08:18 20140825: Saving Configuration file: C:\PADS Data\20140825\PADS.ini 04:08:44 20140825: Acquisition started. 04:09:45 20140825: Acquisition stopped. 04:16:54 20140825: Acquisition started. 04:16:59 20140825: Acquisition stopped. *** 04:16:59 20140825: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. *** 04:17:00 20140825: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 04:17:00 20140825: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 04:17:00 20140825: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 04:17:00 20140825: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. 04:17:06 20140825: PIP Instrument Driver 0, stopped. 04:17:06 20140825: CIP Instrument Driver 1, stopped. 04:17:06 20140825: CDP Instrument Driver 2, stopped. 04:17:06 20140825: Hotwire_LWC Instrument Driver 3, stopped. 04:17:06 20140825: CAS Instrument Driver 4, stopped. 04:17:06 20140825: PBP Instrument Driver 5, stopped. 04:17:06 20140825: CCP Summary Instrument Driver 6, stopped. 04:17:08 20140825: PADS program stopped. 05:56:02 20140825: PADS program started. 05:56:02 20140825: PIP Instrument Driver 0 started. 05:56:02 20140825: Enabling Instrument #0, PIP. 05:56:02 20140825: CIP Instrument Driver 1 started. 05:56:02 20140825: Enabling Instrument #1, CIP. 05:56:03 20140825: CDP Instrument Driver 2 started. 05:56:03 20140825: Enabling Instrument #2, CDP. 05:56:03 20140825: Hotwire_LWC Instrument Driver 3 started. 05:56:05 20140825: CAS Instrument Driver 4 started. 05:56:05 20140825: Enabling Instrument #4, CAS. 05:56:05 20140825: PBP Instrument Driver 5 started. 05:56:05 20140825: Enabling Instrument #5, PBP. 05:56:06 20140825: CCP Summary Instrument Driver 6 started. 05:56:06 20140825: Enabling Instrument #6, CCP Summary. 05:56:06 20140825: CCP Summary Display, Display # 6, Instrument # 6, started. 05:56:06 20140825: PBP Display, Display # 5, Instrument # 5, started. 05:56:07 20140825: CAS Display, Display # 4, Instrument # 4, started. 05:56:07 20140825: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 05:56:07 20140825: CDP Display, Display # 2, Instrument # 2, started. 05:56:07 20140825: CIP Display, Display # 1, Instrument # 1, started. 05:56:08 20140825: PIP Display, Display # 0, Instrument # 0, started. 05:56:08 20140825: Saving Configuration file: C:\PADS Data\20140825\PADS.ini 05:56:15 20140825: Acquisition started. 09:04:20 20140825: Acquisition stopped. 09:04:24 20140825: Acquisition started. 09:04:33 20140825: Acquisition stopped. 09:04:37 20140825: PIP Instrument Driver 0, stopped. 09:04:37 20140825: CIP Instrument Driver 1, stopped. 09:04:37 20140825: CDP Instrument Driver 2, stopped. 09:04:37 20140825: Hotwire_LWC Instrument Driver 3, stopped. 09:04:37 20140825: CAS Instrument Driver 4, stopped. 09:04:37 20140825: PBP Instrument Driver 5, stopped. 09:04:37 20140825: CCP Summary Instrument Driver 6, stopped. 09:04:39 20140825: PADS program stopped. 09:04:59 20140825: PADS program started. 09:04:59 20140825: PIP Instrument Driver 0 started. 09:05:00 20140825: Enabling Instrument #0, PIP. 09:05:00 20140825: CIP Instrument Driver 1 started. 09:05:00 20140825: Enabling Instrument #1, CIP. 09:05:00 20140825: CDP Instrument Driver 2 started. 09:05:00 20140825: Enabling Instrument #2, CDP. 09:05:00 20140825: Hotwire_LWC Instrument Driver 3 started. 09:05:02 20140825: CAS Instrument Driver 4 started. 09:05:02 20140825: Enabling Instrument #4, CAS. 09:05:02 20140825: PBP Instrument Driver 5 started. 09:05:02 20140825: Enabling Instrument #5, PBP. 09:05:03 20140825: CCP Summary Instrument Driver 6 started. 09:05:03 20140825: Enabling Instrument #6, CCP Summary. 09:05:03 20140825: CCP Summary Display, Display # 6, Instrument # 6, started. 09:05:03 20140825: PBP Display, Display # 5, Instrument # 5, started. 09:05:03 20140825: CAS Display, Display # 4, Instrument # 4, started. 09:05:04 20140825: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 09:05:04 20140825: CDP Display, Display # 2, Instrument # 2, started. 09:05:04 20140825: CIP Display, Display # 1, Instrument # 1, started. 09:05:04 20140825: PIP Display, Display # 0, Instrument # 0, started. 09:05:04 20140825: Saving Configuration file: C:\PADS Data\20140825\PADS.ini 09:06:11 20140825: Acquisition started. 13:38:46 20140825: Acquisition stopped. 13:38:46 20140825: Instrument Driver 2, CDP, is being initialized. *** 13:38:47 20140825: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. *** 13:38:47 20140825: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 13:38:47 20140825: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 13:38:47 20140825: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 13:38:47 20140825: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. 13:38:51 20140825: PIP Instrument Driver 0, stopped. 13:38:51 20140825: CIP Instrument Driver 1, stopped. 13:38:51 20140825: CDP Instrument Driver 2, stopped. 13:38:51 20140825: Hotwire_LWC Instrument Driver 3, stopped. 13:38:51 20140825: CAS Instrument Driver 4, stopped. 13:38:51 20140825: PBP Instrument Driver 5, stopped. 13:38:51 20140825: CCP Summary Instrument Driver 6, stopped. 13:38:53 20140825: PADS program stopped.