04:29:41 20130914: PADS program started. 04:29:41 20130914: PIP Instrument Driver 0 started. 04:29:42 20130914: Enabling Instrument #0, PIP. 04:29:42 20130914: CIP Instrument Driver 1 started. 04:29:42 20130914: Enabling Instrument #1, CIP. 04:29:42 20130914: CDP Instrument Driver 2 started. 04:29:42 20130914: Enabling Instrument #2, CDP. 04:29:43 20130914: Hotwire_LWC Instrument Driver 3 started. 04:29:45 20130914: CAS Instrument Driver 4 started. 04:29:45 20130914: Enabling Instrument #4, CAS. 04:29:45 20130914: PBP Instrument Driver 5 started. 04:29:45 20130914: Enabling Instrument #5, PBP. 04:29:46 20130914: CCP Summary Instrument Driver 6 started. 04:29:46 20130914: Enabling Instrument #6, CCP Summary. 04:29:47 20130914: CCP Summary Display, Display # 6, Instrument # 6, started. 04:29:47 20130914: PBP Display, Display # 5, Instrument # 5, started. 04:29:47 20130914: CAS Display, Display # 4, Instrument # 4, started. 04:29:47 20130914: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 04:29:49 20130914: CDP Display, Display # 2, Instrument # 2, started. 04:29:50 20130914: CIP Display, Display # 1, Instrument # 1, started. 04:29:50 20130914: PIP Display, Display # 0, Instrument # 0, started. 04:29:50 20130914: Saving Configuration file: C:\PADS Data\20130914\PADS.ini 04:29:53 20130914: Acquisition started. 04:30:27 20130914: Acquisition stopped. *** 04:30:27 20130914: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. 04:30:36 20130914: PIP Instrument Driver 0, stopped. 04:30:36 20130914: CIP Instrument Driver 1, stopped. 04:30:36 20130914: CDP Instrument Driver 2, stopped. 04:30:36 20130914: Hotwire_LWC Instrument Driver 3, stopped. 04:30:36 20130914: CAS Instrument Driver 4, stopped. 04:30:36 20130914: PBP Instrument Driver 5, stopped. 04:30:36 20130914: CCP Summary Instrument Driver 6, stopped. 04:30:38 20130914: PADS program stopped. 05:59:24 20130914: PADS program started. 05:59:24 20130914: PIP Instrument Driver 0 started. 05:59:24 20130914: Enabling Instrument #0, PIP. 05:59:25 20130914: CIP Instrument Driver 1 started. 05:59:25 20130914: Enabling Instrument #1, CIP. 05:59:25 20130914: CDP Instrument Driver 2 started. 05:59:25 20130914: Enabling Instrument #2, CDP. 05:59:25 20130914: Hotwire_LWC Instrument Driver 3 started. 05:59:27 20130914: CAS Instrument Driver 4 started. 05:59:27 20130914: Enabling Instrument #4, CAS. 05:59:27 20130914: PBP Instrument Driver 5 started. 05:59:27 20130914: Enabling Instrument #5, PBP. 05:59:28 20130914: CCP Summary Instrument Driver 6 started. 05:59:28 20130914: Enabling Instrument #6, CCP Summary. 05:59:28 20130914: CCP Summary Display, Display # 6, Instrument # 6, started. 05:59:28 20130914: PBP Display, Display # 5, Instrument # 5, started. 05:59:28 20130914: CAS Display, Display # 4, Instrument # 4, started. 05:59:28 20130914: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 05:59:29 20130914: CDP Display, Display # 2, Instrument # 2, started. 05:59:29 20130914: CIP Display, Display # 1, Instrument # 1, started. 05:59:29 20130914: PIP Display, Display # 0, Instrument # 0, started. 05:59:29 20130914: Saving Configuration file: C:\PADS Data\20130914\PADS.ini 05:59:32 20130914: Acquisition started. 14:10:21 20130914: Acquisition stopped. *** 14:10:21 20130914: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. *** 14:10:22 20130914: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 14:10:22 20130914: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 14:10:22 20130914: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. *** 14:10:22 20130914: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. 14:10:25 20130914: PIP Instrument Driver 0, stopped. 14:10:25 20130914: CIP Instrument Driver 1, stopped. 14:10:25 20130914: CDP Instrument Driver 2, stopped. 14:10:25 20130914: Hotwire_LWC Instrument Driver 3, stopped. 14:10:25 20130914: CAS Instrument Driver 4, stopped. 14:10:25 20130914: PBP Instrument Driver 5, stopped. 14:10:25 20130914: CCP Summary Instrument Driver 6, stopped. 14:10:27 20130914: PADS program stopped.