15:21:05 20130616: PADS program started. 15:21:05 20130616: PIP Instrument Driver 0 started. 15:21:06 20130616: Enabling Instrument #0, PIP. 15:21:06 20130616: CIP Instrument Driver 1 started. 15:21:06 20130616: Enabling Instrument #1, CIP. 15:21:06 20130616: CDP Instrument Driver 2 started. 15:21:06 20130616: Enabling Instrument #2, CDP. 15:21:07 20130616: Hotwire_LWC Instrument Driver 3 started. 15:21:08 20130616: CAS Instrument Driver 4 started. 15:21:08 20130616: Enabling Instrument #4, CAS. 15:21:09 20130616: PBP Instrument Driver 5 started. 15:21:09 20130616: Enabling Instrument #5, PBP. 15:21:09 20130616: CCP Summary Instrument Driver 6 started. 15:21:09 20130616: Enabling Instrument #6, CCP Summary. 15:21:09 20130616: CCP Summary Display, Display # 6, Instrument # 6, started. 15:21:10 20130616: PBP Display, Display # 5, Instrument # 5, started. 15:21:10 20130616: CAS Display, Display # 4, Instrument # 4, started. 15:21:10 20130616: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 15:21:10 20130616: CDP Display, Display # 2, Instrument # 2, started. 15:21:11 20130616: CIP Display, Display # 1, Instrument # 1, started. 15:21:11 20130616: PIP Display, Display # 0, Instrument # 0, started. 15:21:11 20130616: Saving Configuration file: C:\PADS Data\20130616\PADS.ini 15:21:13 20130616: Acquisition started. 21:49:55 20130616: Acquisition stopped. *** 21:49:55 20130616: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 21:49:56 20130616: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 21:49:56 20130616: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 21:49:56 20130616: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. *** 21:49:56 20130616: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. 21:50:07 20130616: PIP Instrument Driver 0, stopped. 21:50:07 20130616: CIP Instrument Driver 1, stopped. 21:50:07 20130616: CDP Instrument Driver 2, stopped. 21:50:07 20130616: Hotwire_LWC Instrument Driver 3, stopped. 21:50:07 20130616: CAS Instrument Driver 4, stopped. 21:50:07 20130616: PBP Instrument Driver 5, stopped. 21:50:07 20130616: CCP Summary Instrument Driver 6, stopped. 21:50:11 20130616: PADS program stopped.