14:39:11 20130612: PADS program started. 14:39:11 20130612: PIP Instrument Driver 0 started. 14:39:12 20130612: Enabling Instrument #0, PIP. 14:39:12 20130612: CIP Instrument Driver 1 started. 14:39:12 20130612: Enabling Instrument #1, CIP. 14:39:12 20130612: CDP Instrument Driver 2 started. 14:39:13 20130612: Enabling Instrument #2, CDP. 14:39:13 20130612: Hotwire_LWC Instrument Driver 3 started. 14:39:15 20130612: CAS Instrument Driver 4 started. 14:39:15 20130612: Enabling Instrument #4, CAS. 14:39:15 20130612: PBP Instrument Driver 5 started. 14:39:15 20130612: Enabling Instrument #5, PBP. 14:39:15 20130612: CCP Summary Instrument Driver 6 started. 14:39:16 20130612: Enabling Instrument #6, CCP Summary. 14:39:16 20130612: CCP Summary Display, Display # 6, Instrument # 6, started. 14:39:16 20130612: PBP Display, Display # 5, Instrument # 5, started. 14:39:16 20130612: CAS Display, Display # 4, Instrument # 4, started. 14:39:17 20130612: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 14:39:17 20130612: CDP Display, Display # 2, Instrument # 2, started. 14:39:18 20130612: CIP Display, Display # 1, Instrument # 1, started. 14:39:18 20130612: PIP Display, Display # 0, Instrument # 0, started. 14:39:18 20130612: Saving Configuration file: C:\PADS Data\20130612\PADS.ini 14:40:20 20130612: Acquisition started. 20:32:53 20130612: Acquisition stopped. 20:32:53 20130612: Instrument Driver 5,PBP, is being initialized. *** 20:32:53 20130612: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. *** 20:32:53 20130612: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 20:32:53 20130612: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 20:32:53 20130612: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 20:32:54 20130612: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. 20:32:55 20130612: PIP Instrument Driver 0, stopped. 20:32:55 20130612: CIP Instrument Driver 1, stopped. 20:32:55 20130612: CDP Instrument Driver 2, stopped. 20:32:55 20130612: Hotwire_LWC Instrument Driver 3, stopped. 20:32:55 20130612: CAS Instrument Driver 4, stopped. 20:32:55 20130612: PBP Instrument Driver 5, stopped. 20:32:55 20130612: CCP Summary Instrument Driver 6, stopped. 20:32:58 20130612: PADS program stopped.