21:46:50 20130202: PADS program started. 21:46:50 20130202: PIP Instrument Driver 0 started. 21:46:50 20130202: Enabling Instrument #0, PIP. 21:46:50 20130202: CIP Instrument Driver 1 started. 21:46:50 20130202: Enabling Instrument #1, CIP. 21:46:51 20130202: CDP Instrument Driver 2 started. 21:46:51 20130202: Enabling Instrument #2, CDP. 21:46:51 20130202: Hotwire_LWC Instrument Driver 3 started. 21:46:53 20130202: CAS Instrument Driver 4 started. 21:46:53 20130202: Enabling Instrument #4, CAS. 21:46:53 20130202: PBP Instrument Driver 5 started. 21:46:53 20130202: Enabling Instrument #5, PBP. 21:46:53 20130202: CCP Summary Instrument Driver 6 started. 21:46:54 20130202: Enabling Instrument #6, CCP Summary. 21:46:54 20130202: CCP Summary Display, Display # 6, Instrument # 6, started. 21:46:54 20130202: PBP Display, Display # 5, Instrument # 5, started. 21:46:54 20130202: CAS Display, Display # 4, Instrument # 4, started. 21:46:55 20130202: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 21:46:55 20130202: CDP Display, Display # 2, Instrument # 2, started. 21:46:55 20130202: CIP Display, Display # 1, Instrument # 1, started. 21:46:55 20130202: PIP Display, Display # 0, Instrument # 0, started. 21:46:56 20130202: Saving Configuration file: C:\PADS Data\20130202\PADS.ini 21:46:51 20130202: Acquisition started. 06:26:15 20130203: Acquisition stopped. 06:26:15 20130203: Instrument Driver 0,PIP, is being initialized. 06:26:15 20130203: Instrument Driver 5,PBP, is being initialized. *** 06:26:15 20130203: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. *** 06:26:16 20130203: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 06:26:16 20130203: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 06:26:16 20130203: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 06:26:16 20130203: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. 06:26:20 20130203: PIP Instrument Driver 0, stopped. 06:26:20 20130203: CIP Instrument Driver 1, stopped. 06:26:20 20130203: CDP Instrument Driver 2, stopped. 06:26:20 20130203: Hotwire_LWC Instrument Driver 3, stopped. 06:26:20 20130203: CAS Instrument Driver 4, stopped. 06:26:20 20130203: PBP Instrument Driver 5, stopped. 06:26:20 20130203: CCP Summary Instrument Driver 6, stopped. 06:26:22 20130203: PADS program stopped.