20:06:17 20121025: PADS program started. 20:06:17 20121025: PIP Instrument Driver 0 started. 20:06:17 20121025: Enabling Instrument #0, PIP. 20:06:17 20121025: CIP Instrument Driver 1 started. 20:06:17 20121025: Enabling Instrument #1, CIP. 20:06:18 20121025: CDP Instrument Driver 2 started. 20:06:18 20121025: Enabling Instrument #2, CDP. 20:06:18 20121025: Hotwire_LWC Instrument Driver 3 started. 20:06:20 20121025: CAS Instrument Driver 4 started. 20:06:20 20121025: Enabling Instrument #4, CAS. 20:06:20 20121025: PBP Instrument Driver 5 started. 20:06:20 20121025: Enabling Instrument #5, PBP. 20:06:20 20121025: CCP Summary Instrument Driver 6 started. 20:06:21 20121025: Enabling Instrument #6, CCP Summary. 20:06:21 20121025: CCP Summary Display, Display # 6, Instrument # 6, started. 20:06:21 20121025: PBP Display, Display # 5, Instrument # 5, started. 20:06:22 20121025: CAS Display, Display # 4, Instrument # 4, started. 20:06:22 20121025: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 20:06:22 20121025: CDP Display, Display # 2, Instrument # 2, started. 20:06:22 20121025: CIP Display, Display # 1, Instrument # 1, started. 20:06:23 20121025: PIP Display, Display # 0, Instrument # 0, started. 20:06:23 20121025: Saving Configuration file: C:\PADS Data\20121025\PADS.ini 20:08:45 20121025: Acquisition started. 04:26:46 20121026: Acquisition stopped. *** 04:26:46 20121026: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 04:26:46 20121026: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 04:26:46 20121026: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. *** 04:26:47 20121026: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 04:26:47 20121026: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. 04:26:51 20121026: PIP Instrument Driver 0, stopped. 04:26:51 20121026: CIP Instrument Driver 1, stopped. 04:26:51 20121026: CDP Instrument Driver 2, stopped. 04:26:51 20121026: Hotwire_LWC Instrument Driver 3, stopped. 04:26:51 20121026: CAS Instrument Driver 4, stopped. 04:26:51 20121026: PBP Instrument Driver 5, stopped. 04:26:51 20121026: CCP Summary Instrument Driver 6, stopped. 04:26:53 20121026: PADS program stopped.