11:41:46 20120816: PADS program started. 11:41:46 20120816: PIP Instrument Driver 0 started. 11:41:46 20120816: Enabling Instrument #0, PIP. 11:41:47 20120816: CIP Instrument Driver 1 started. 11:41:47 20120816: Enabling Instrument #1, CIP. 11:41:47 20120816: CDP Instrument Driver 2 started. 11:41:47 20120816: Enabling Instrument #2, CDP. 11:41:47 20120816: Hotwire_LWC Instrument Driver 3 started. 11:41:49 20120816: CAS Instrument Driver 4 started. 11:41:49 20120816: Enabling Instrument #4, CAS. 11:41:49 20120816: PBP Instrument Driver 5 started. 11:41:50 20120816: Enabling Instrument #5, PBP. 11:41:50 20120816: CCP Summary Instrument Driver 6 started. 11:41:50 20120816: Enabling Instrument #6, CCP Summary. 11:41:50 20120816: CCP Summary Display, Display # 6, Instrument # 6, started. 11:41:51 20120816: PBP Display, Display # 5, Instrument # 5, started. 11:41:51 20120816: CAS Display, Display # 4, Instrument # 4, started. 11:41:51 20120816: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 11:41:51 20120816: CDP Display, Display # 2, Instrument # 2, started. 11:41:52 20120816: CIP Display, Display # 1, Instrument # 1, started. 11:41:52 20120816: PIP Display, Display # 0, Instrument # 0, started. 11:41:52 20120816: Saving Configuration file: C:\PADS Data\20120816\PADS.ini 11:42:12 20120816: Acquisition started. 11:42:37 20120816: Instrument Driver 0,PIP, is being initialized. 11:42:37 20120816: Acquisition stopped. 11:42:37 20120816: Instrument Driver 4,CAS, is being initialized. *** 11:42:37 20120816: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 11:42:37 20120816: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. *** 11:42:37 20120816: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 11:42:38 20120816: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. *** 11:42:38 20120816: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. 12:59:18 20120816: PADS program started. 12:59:18 20120816: PIP Instrument Driver 0 started. 12:59:18 20120816: Enabling Instrument #0, PIP. 12:59:18 20120816: CIP Instrument Driver 1 started. 12:59:18 20120816: Enabling Instrument #1, CIP. 12:59:19 20120816: CDP Instrument Driver 2 started. 12:59:19 20120816: Enabling Instrument #2, CDP. 12:59:19 20120816: Hotwire_LWC Instrument Driver 3 started. 12:59:21 20120816: CAS Instrument Driver 4 started. 12:59:21 20120816: Enabling Instrument #4, CAS. 12:59:21 20120816: PBP Instrument Driver 5 started. 12:59:21 20120816: Enabling Instrument #5, PBP. 12:59:21 20120816: CCP Summary Instrument Driver 6 started. 12:59:22 20120816: Enabling Instrument #6, CCP Summary. 12:59:22 20120816: CCP Summary Display, Display # 6, Instrument # 6, started. 12:59:22 20120816: PBP Display, Display # 5, Instrument # 5, started. 12:59:23 20120816: CAS Display, Display # 4, Instrument # 4, started. 12:59:23 20120816: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 12:59:23 20120816: CDP Display, Display # 2, Instrument # 2, started. 12:59:23 20120816: CIP Display, Display # 1, Instrument # 1, started. 12:59:24 20120816: PIP Display, Display # 0, Instrument # 0, started. 12:59:24 20120816: Saving Configuration file: C:\PADS Data\20120816\PADS.ini 12:59:30 20120816: Acquisition started. 20:25:11 20120816: Acquisition stopped.