07:25:34 20111209: PADS program started. 07:25:34 20111209: PIP Instrument Driver 0 started. 07:25:34 20111209: Enabling Instrument #0, PIP. 07:25:34 20111209: CIP Instrument Driver 1 started. 07:25:35 20111209: Enabling Instrument #1, CIP. 07:25:35 20111209: CDP Instrument Driver 2 started. 07:25:35 20111209: Enabling Instrument #2, CDP. 07:25:35 20111209: Hotwire_LWC Instrument Driver 3 started. 07:25:37 20111209: CAS Instrument Driver 4 started. 07:25:37 20111209: Enabling Instrument #4, CAS. 07:25:38 20111209: PBP Instrument Driver 5 started. 07:25:38 20111209: Enabling Instrument #5, PBP. 07:25:38 20111209: CCP Summary Instrument Driver 6 started. 07:25:38 20111209: Enabling Instrument #6, CCP Summary. 07:25:39 20111209: CCP Summary Display, Display # 6, Instrument # 6, started. 07:25:39 20111209: PBP Display, Display # 5, Instrument # 5, started. 07:25:40 20111209: CAS Display, Display # 4, Instrument # 4, started. 07:25:40 20111209: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 07:25:43 20111209: CDP Display, Display # 2, Instrument # 2, started. 07:25:43 20111209: CIP Display, Display # 1, Instrument # 1, started. 07:25:44 20111209: PIP Display, Display # 0, Instrument # 0, started. 07:25:44 20111209: Saving Configuration file: C:\PADS Data\20111209\PADS.ini 07:25:46 20111209: Acquisition started. 07:26:16 20111209: Acquisition stopped. 07:26:16 20111209: Instrument Driver 4,CAS, is being initialized. *** 07:26:16 20111209: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. 07:26:16 20111209: PIP Instrument Driver 0, stopped. 07:26:16 20111209: CIP Instrument Driver 1, stopped. 07:26:16 20111209: CDP Instrument Driver 2, stopped. 07:26:16 20111209: Hotwire_LWC Instrument Driver 3, stopped. 07:26:16 20111209: CAS Instrument Driver 4, stopped. 07:26:16 20111209: PBP Instrument Driver 5, stopped. 07:26:16 20111209: CCP Summary Instrument Driver 6, stopped. 07:26:18 20111209: PADS program stopped. 07:26:51 20111209: PADS program started. 07:26:51 20111209: PIP Instrument Driver 0 started. 07:26:51 20111209: Enabling Instrument #0, PIP. 07:26:51 20111209: CIP Instrument Driver 1 started. 07:26:51 20111209: Enabling Instrument #1, CIP. 07:26:51 20111209: CDP Instrument Driver 2 started. 07:26:51 20111209: Enabling Instrument #2, CDP. 07:26:52 20111209: Hotwire_LWC Instrument Driver 3 started. 07:26:53 20111209: CAS Instrument Driver 4 started. 07:26:53 20111209: Enabling Instrument #4, CAS. 07:26:54 20111209: PBP Instrument Driver 5 started. 07:26:54 20111209: Enabling Instrument #5, PBP. 07:26:54 20111209: CCP Summary Instrument Driver 6 started. 07:26:54 20111209: Enabling Instrument #6, CCP Summary. 07:26:54 20111209: CCP Summary Display, Display # 6, Instrument # 6, started. 07:26:54 20111209: PBP Display, Display # 5, Instrument # 5, started. 07:26:55 20111209: CAS Display, Display # 4, Instrument # 4, started. 07:26:55 20111209: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 07:26:55 20111209: CDP Display, Display # 2, Instrument # 2, started. 07:26:55 20111209: CIP Display, Display # 1, Instrument # 1, started. 07:26:55 20111209: PIP Display, Display # 0, Instrument # 0, started. 07:26:56 20111209: Saving Configuration file: C:\PADS Data\20111209\PADS.ini 07:27:03 20111209: Acquisition started. 07:27:27 20111209: Acquisition stopped. *** 07:27:28 20111209: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. 07:27:35 20111209: PIP Instrument Driver 0, stopped. 07:27:35 20111209: CIP Instrument Driver 1, stopped. 07:27:35 20111209: CDP Instrument Driver 2, stopped. 07:27:35 20111209: Hotwire_LWC Instrument Driver 3, stopped. 07:27:35 20111209: CAS Instrument Driver 4, stopped. 07:27:35 20111209: PBP Instrument Driver 5, stopped. 07:27:35 20111209: CCP Summary Instrument Driver 6, stopped. 07:27:37 20111209: PADS program stopped. 07:30:14 20111209: PADS program started. 07:30:14 20111209: PIP Instrument Driver 0 started. 07:30:14 20111209: Enabling Instrument #0, PIP. 07:30:14 20111209: CIP Instrument Driver 1 started. 07:30:14 20111209: Enabling Instrument #1, CIP. 07:30:15 20111209: CDP Instrument Driver 2 started. 07:30:15 20111209: Enabling Instrument #2, CDP. 07:30:15 20111209: Hotwire_LWC Instrument Driver 3 started. 07:30:17 20111209: CAS Instrument Driver 4 started. 07:30:17 20111209: Enabling Instrument #4, CAS. 07:30:17 20111209: PBP Instrument Driver 5 started. 07:30:17 20111209: Enabling Instrument #5, PBP. 07:30:17 20111209: CCP Summary Instrument Driver 6 started. 07:30:18 20111209: Enabling Instrument #6, CCP Summary. 07:30:18 20111209: CCP Summary Display, Display # 6, Instrument # 6, started. 07:30:19 20111209: PBP Display, Display # 5, Instrument # 5, started. 07:30:19 20111209: CAS Display, Display # 4, Instrument # 4, started. 07:30:19 20111209: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 07:30:22 20111209: CDP Display, Display # 2, Instrument # 2, started. 07:30:23 20111209: CIP Display, Display # 1, Instrument # 1, started. 07:30:23 20111209: PIP Display, Display # 0, Instrument # 0, started. 07:30:23 20111209: Saving Configuration file: C:\PADS Data\20111209\PADS.ini 07:30:30 20111209: Acquisition started. 07:30:44 20111209: Acquisition stopped. *** 07:30:44 20111209: Error 5902 occurred at CAS Initialize.vi > CAS 11.vi Possible reason(s): Instrument did not respond properly to setup command. 07:30:47 20111209: PIP Instrument Driver 0, stopped. 07:30:47 20111209: CIP Instrument Driver 1, stopped. 07:30:47 20111209: CDP Instrument Driver 2, stopped. 07:30:47 20111209: Hotwire_LWC Instrument Driver 3, stopped. 07:30:47 20111209: CAS Instrument Driver 4, stopped. 07:30:47 20111209: PBP Instrument Driver 5, stopped. 07:30:47 20111209: CCP Summary Instrument Driver 6, stopped. 07:30:49 20111209: PADS program stopped. 07:35:02 20111209: PADS program started. 07:35:02 20111209: PIP Instrument Driver 0 started. 07:35:02 20111209: Enabling Instrument #0, PIP. 07:35:02 20111209: CIP Instrument Driver 1 started. 07:35:02 20111209: Enabling Instrument #1, CIP. 07:35:02 20111209: CDP Instrument Driver 2 started. 07:35:03 20111209: Enabling Instrument #2, CDP. 07:35:03 20111209: Hotwire_LWC Instrument Driver 3 started. 07:35:05 20111209: CAS Instrument Driver 4 started. 07:35:05 20111209: Enabling Instrument #4, CAS. 07:35:05 20111209: PBP Instrument Driver 5 started. 07:35:05 20111209: Enabling Instrument #5, PBP. 07:35:06 20111209: CCP Summary Instrument Driver 6 started. 07:35:06 20111209: Enabling Instrument #6, CCP Summary. 07:35:07 20111209: CCP Summary Display, Display # 6, Instrument # 6, started. 07:35:07 20111209: PBP Display, Display # 5, Instrument # 5, started. 07:35:07 20111209: CAS Display, Display # 4, Instrument # 4, started. 07:35:07 20111209: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 07:35:08 20111209: CDP Display, Display # 2, Instrument # 2, started. 07:35:08 20111209: CIP Display, Display # 1, Instrument # 1, started. 07:35:08 20111209: PIP Display, Display # 0, Instrument # 0, started. 07:35:08 20111209: Saving Configuration file: C:\PADS Data\20111209\PADS.ini 07:35:19 20111209: Acquisition started. 07:37:07 20111209: Acquisition stopped. *** 07:37:07 20111209: Error -1073807339 occurred at VISA Read in PBP Read Data.vi->PBP Get Data.vi->PBP 13.vi Possible reason(s): VISA: (Hex 0xBFFF0015) Timeout expired before operation completed. *** 07:37:07 20111209: Error 5902 occurred at CDP Initialize.vi > CDP 7.vi Possible reason(s): Instrument did not respond properly to setup command. *** 07:37:07 20111209: Error 5902 occurred at CIP Initialize.vi > CIP 4.vi Possible reason(s): Instrument did not respond properly to setup command. *** 07:37:07 20111209: Error 5902 occurred at PIP Initialize.vi > PIP 1.vi Possible reason(s): Instrument did not respond properly to setup command. 07:39:36 20111209: PIP Instrument Driver 0, stopped. 07:39:36 20111209: CIP Instrument Driver 1, stopped. 07:39:36 20111209: CDP Instrument Driver 2, stopped. 07:39:36 20111209: Hotwire_LWC Instrument Driver 3, stopped. 07:39:36 20111209: CAS Instrument Driver 4, stopped. 07:39:36 20111209: PBP Instrument Driver 5, stopped. 07:39:36 20111209: CCP Summary Instrument Driver 6, stopped. 07:39:38 20111209: PADS program stopped. 07:39:42 20111209: PADS program started. 07:39:42 20111209: PIP Instrument Driver 0 started. 07:39:42 20111209: Enabling Instrument #0, PIP. 07:39:42 20111209: CIP Instrument Driver 1 started. 07:39:42 20111209: Enabling Instrument #1, CIP. 07:39:42 20111209: CDP Instrument Driver 2 started. 07:39:42 20111209: Enabling Instrument #2, CDP. 07:39:43 20111209: Hotwire_LWC Instrument Driver 3 started. 07:39:44 20111209: CAS Instrument Driver 4 started. 07:39:44 20111209: Enabling Instrument #4, CAS. 07:39:45 20111209: PBP Instrument Driver 5 started. 07:39:45 20111209: Enabling Instrument #5, PBP. 07:39:45 20111209: CCP Summary Instrument Driver 6 started. 07:39:45 20111209: Enabling Instrument #6, CCP Summary. 07:39:45 20111209: CCP Summary Display, Display # 6, Instrument # 6, started. 07:39:46 20111209: PBP Display, Display # 5, Instrument # 5, started. 07:39:46 20111209: CAS Display, Display # 4, Instrument # 4, started. 07:39:46 20111209: Hotwire_LWC Display, Display # 3, Instrument # 3, started. 07:39:46 20111209: CDP Display, Display # 2, Instrument # 2, started. 07:39:46 20111209: CIP Display, Display # 1, Instrument # 1, started. 07:39:47 20111209: PIP Display, Display # 0, Instrument # 0, started. 07:39:47 20111209: Saving Configuration file: C:\PADS Data\20111209\PADS.ini 07:39:57 20111209: Acquisition started. 07:40:44 20111209: Acquisition stopped. 07:40:47 20111209: PIP Instrument Driver 0, stopped. 07:40:47 20111209: CIP Instrument Driver 1, stopped. 07:40:47 20111209: CDP Instrument Driver 2, stopped. 07:40:47 20111209: Hotwire_LWC Instrument Driver 3, stopped. 07:40:47 20111209: CAS Instrument Driver 4, stopped. 07:40:47 20111209: PBP Instrument Driver 5, stopped. 07:40:47 20111209: CCP Summary Instrument Driver 6, stopped. 07:40:49 20111209: PADS program stopped.